  • 摘要: 针对类管路系统密封性检测需求,对基于温度和压力变化的保压法进行研究,分析小管路泄漏率检测的影响因素,提出温度补偿模型;分析满足管路泄漏率的设计指标,管路检漏系统需要的检测时间以及温度和压力传感器的参数要求;通过某型类管路系统的试验完成了保压法测量小管路泄漏率的验证。试验结果表明,基于温度补偿模型的保压法,具有较好的泄漏率检测精度。研究结果可为解决航天系统工质补给类管路系统的泄漏率检测提供思路。

     

    Abstract: To meet the sealing test requirements of pipeline-like systems, a pressure maintaining method based on temperature and pressure changes was presented. The influencing factors of leakage rate detection for small pipelines were analyzed. A temperature compensation model was proposed. The pipeline leakage rate detection indicators, the required detection time, and the requirements for temperature and pressure sensor parameters were analyzed. Through tests on a pipeline-like system, the verification of the leakage rate detection of the small pipeline measured by the proposed method was completed. It is shown that the pressure maintaining method based on temperature compensation model has good accuracy for leakage rate detection. The results may provide ideas for solving the leakage rate detection of working fluid resupply pipelines in space system.

     

/