卫星导电铜箔接地性能退化机理研究

The degradation mechanism of the grounding performance of spacecraft’s copper foil

  • 摘要: 接地网的接地性能关系整星电磁兼容性的优劣。文章从接地网导电铜箔的搭接现状入手,分析铜箔本身和导电胶的电阻以及铜箔接地电阻退化的机理;通过温湿度加速试验验证指出,在导电铜箔接地性能退化中导电胶的性能退化起主导作用;通过工艺试验得出电焊可以显著改善铜箔接地性能,以满足型号任务需求。

     

    Abstract: The grounding network assembled during the satellite AIT phase is closely related with the quality of the EMC performance. This paper reviews the present status of the conductive copper foil grounding performance and analyzes the degradation mechanism of the conductive copper foil grounding performance. By carrying out a humiture acceleration test, it is found that the conductive adhesive degradation plays a dominant role. Besides, the spot-welding can obviously improve the grounding performance of the copper foil so as to meet the demands of the satellite mission.

     

/

返回文章